ATTO Technology 2200R Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Nie ATTO Technology 2200R. ATTO Technology 2200R Product data Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 66
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
ATTO
ATTO Technology, Inc.
ATTO FibreBridge
Product Modules
Software Manual
ATTO FibreBridge 2100R, 2200 R/D, 3100R and 3200R Product Modules
© 2000 ATTO Technology, Incorporated. All rights reserved. All brand or product names are trademarks of their respective holders.
No part of this manual may be reproduced in any form or by any means without the express written permission of ATTO
Technology, Incorporated.
Rev. D, 01/01 Document Control Number: PRMA-0219-000
Przeglądanie stron 0
1 2 3 4 5 6 ... 65 66

Podsumowanie treści

Strona 1 - Product Modules

ATTOATTO Technology, Inc.ATTO FibreBridge Product ModulesSoftware ManualATTO FibreBridge 2100R, 2200 R/D, 3100R and 3200R Product Modules© 2000 ATTO

Strona 2

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -5ATTO Technology, Inc.Chapter 3: Command Line Interface (ATTO FibreBridge 2200R/D, 3

Strona 3 - Table of Contents

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -6ATTO Technology, Inc.ATTO FibreBridge Configuration Service CommandsFcAck0 (ATTO Fi

Strona 4

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -7ATTO Technology, Inc.Specifies the translation rules applied to fibre channel LUNs

Strona 5

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -8ATTO Technology, Inc.The FcFullDuplex command is used to enable or disable full dup

Strona 6 - System Diagnostic Services

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -9ATTO Technology, Inc.FibreBridgeNameSyntax: set FibreBridgeName [name]get FibreBrid

Strona 7

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -10ATTO Technology, Inc.Returns: (terse) nn (verbose) RequestQueue Length = nnSpe

Strona 8 - Initial Display (RS-232)

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -11ATTO Technology, Inc.ScsiPortSelTimeoutSyntax: set ScsiPortSelTimeout [PortNumbe

Strona 9 - -

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -12ATTO Technology, Inc.ScsiPortWideTransferSyntax: set ScsiPortWideTransfer [Por

Strona 10

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -13ATTO Technology, Inc.Configures the data handshaking method used for controlling t

Strona 11

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -14ATTO Technology, Inc.ScsiPortReset (Immediate)Syntax: ScsiPortReset [PortNumber]R

Strona 12

ATTO Technology, Inc. ATTO FibreBridge Software Manual-i-ATTO Technology, Inc.

Strona 13

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -15ATTO Technology, Inc.ErrorLog for ATTO FibreBridge 3100RSyntax: set ErrorLog clear

Strona 14

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -16ATTO Technology, Inc.the logical OR of the corresponding subsystem values. To dis

Strona 15

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -17ATTO Technology, Inc.DisplayEvent (Immediate)Syntax: DisplayEvent <all>Retur

Strona 16

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -18ATTO Technology, Inc.Set/Display the current subnet mask. If IPDHCP is enabled, t

Strona 17

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -19ATTO Technology, Inc.Menu (Immediate)Syntax: Menu <[enabled | disabled]>Retu

Strona 18

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -20ATTO Technology, Inc.VerboseModeSyntax: set VerboseMode [enabled | disabled]get Ve

Strona 19

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -21ATTO Technology, Inc.Chapter 4: Menu Interface for ATTO FibreBridge 2200 R/D, 3100

Strona 20

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -22ATTO Technology, Inc.ATTO FibreBridge Maintenance MenuFibreBridge Maintenance Menu

Strona 21

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -23ATTO Technology, Inc.Fibre Channel Configuration Menu cont.’dN Class 2 Service Par

Strona 22

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -24ATTO Technology, Inc.Network Configuration MenuNetwork Configuration Menu NotesA E

Strona 23 - Miscellaneous Commands

ATTO Technology, Inc. ATTO FibreBridge Software Manual- i -ATTO Technology, Inc.Table of ContentsCHAPTER 1: ATTO FIBREBRIDGE SERVICES ...

Strona 24

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -25ATTO Technology, Inc.Chapter 5: ATTO FibreBridge SCSI CommandsThis chapter describ

Strona 25

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -26ATTO Technology, Inc.Field DefinitionPeripheral qualifier The peripheral qualifier

Strona 26

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -27ATTO Technology, Inc.Field DefinitionVital Product DataThe Peripheral Qualifier an

Strona 27

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -28ATTO Technology, Inc.Device Identification PageThe Device Identification Page prov

Strona 28

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -29ATTO Technology, Inc.READ 7BUFFER commandThe READ BUFFER command is used in conjun

Strona 29

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -30ATTO Technology, Inc.BitByte7 6 5 4 3 2 1 00 Operation code (A0h)1 Reserved2 Reser

Strona 30

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -31ATTO Technology, Inc.Request Sense CommandBitByte7 6 5 4 3 2 1 00 Operation code (

Strona 31 - Field Definition

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -32ATTO Technology, Inc.transferred. The ATTO FibreBridge will transfer the complete

Strona 32

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -33ATTO Technology, Inc.The ‘Configuration’ page (following) describes the format of

Strona 33

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -34ATTO Technology, Inc.Enclosure Status Page for ATTO FibreBridge 2100RByte0 1 2 30

Strona 34

ATTO Technology, Inc. ATTO FibreBridge Software Manual- ii -ATTO Technology, Inc.LANGUAGE ELEMENT FOR STATUS PAGE...

Strona 35

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -35ATTO Technology, Inc.Enclosure Status Page for ATTO FibreBridge 2200R/D, 3100R and

Strona 36

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -36ATTO Technology, Inc.Element Definitions:Device Element for Status PageBitByte7 6

Strona 37

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -37ATTO Technology, Inc.Xmit Fail: Indicates that the port’s transmitter has failed.

Strona 38

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -38ATTO Technology, Inc.POST Code Element for Status PageBitByte7 6 5 4 3 2 1 00 Comm

Strona 39

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -39ATTO Technology, Inc.Enclosure Control Page for ATTO FibreBridge 2100RByte0 1 2 30

Strona 40

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -40ATTO Technology, Inc.Enclosure Control Page for ATTO FibreBridge 3100R and 3200RBy

Strona 41

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -41ATTO Technology, Inc.Device Element for Control PageBitByte7 6 5 4 3 2 1 00 Common

Strona 42

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -42ATTO Technology, Inc.Languagee Element For Status PageBitByte7 6 5 4 3 2 1 00 Comm

Strona 43

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -43ATTO Technology, Inc.Command Table TemplatesBitByte7 6 5 4 3 2 1 0012345BitByte7 6

Strona 44

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -44ATTO Technology, Inc.Tunnel CDB (ATTO FibreBridge 3100R and 3200R)The Tunnel CDB∗

Strona 45

ATTO Technology, Inc. ATTO FibreBridge Software Manual- iii -ATTO Technology, Inc.

Strona 46

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -45ATTO Technology, Inc.Chapter 6: NVRAM ConfigurationATTO FibreBridge 2100R NVRAM Co

Strona 47

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -46ATTO Technology, Inc.Buffer ID nvram offset Buffer Descript

Strona 48

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -47ATTO Technology, Inc.Buffer ID nvram offset Buffer Description (default val

Strona 49

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -48ATTO Technology, Inc. ATTO FibreBridge 3100R NVRAM Configuration Parameters Summar

Strona 50

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -49ATTO Technology, Inc.Buffer ID nvram offset Buffer Description (default v

Strona 51

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -50ATTO Technology, Inc.Buffer ID nvram offset Buffer Description (default v

Strona 52

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -51ATTO Technology, Inc.Buffer ID nvram offset Buffer Description (default v

Strona 53

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -52ATTO Technology, Inc.ATTO FibreBridge 2200R/D, 3200R NVRAM Configuration Parameter

Strona 54 - : Reserved

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -53ATTO Technology, Inc.Buffer ID nvram offset Buffer Descript

Strona 55

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -54ATTO Technology, Inc.Buffer ID nvram offset Buffer Descript

Strona 56

ATTO Technology, Inc. ATTO FibreBridge Software Manual- -1ATTO Technology, Inc.Chapter 1: ATTO FibreBridge ServicesThis document defines the ATTO Fi

Strona 57

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -55ATTO Technology, Inc.Buffer ID nvram offset Buffer Desc

Strona 58

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -56ATTO Technology, Inc.Buffer ID nvram offset Buffer Descript

Strona 59

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -57ATTO Technology, Inc.Chapter 7: Error CodesThe following is a list of Error Codes

Strona 60

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -58ATTO Technology, Inc.How to Contact ATTO Technology, Inc.For customer service and

Strona 61

ATTO Technology, Inc. ATTO FibreBridge Software Manual-1-ATTO Technology, Inc.INDEXAarbitration fairness, 7ATTO FibreBridge Services, 1, 21, 57auto-ne

Strona 62 - Chapter 7: Error Codes

ATTO Technology, Inc. ATTO FibreBridge Software Manual-2-ATTO Technology, Inc.OOctal numbers, 5PPDAM, 6, 22Physical Device Address Method, 6POST Code,

Strona 63

ATTO Technology, Inc. ATTO FibreBridge Software Manual-3-ATTO Technology, Inc.

Strona 64

ATTO Technology, Inc. ATTO FibreBridge Software Manual- -2ATTO Technology, Inc.

Strona 65

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -3ATTO Technology, Inc.Chapter 2: OperationThere are two methods of operation: Menu I

Strona 66

ATTO Technology, Inc. ATTO FibreBridge Software Manual - -4ATTO Technology, Inc.

Komentarze do niniejszej Instrukcji

Brak uwag